Issues : Errors repeated in EE

b. 271

composition: Op. 16, Rondo in E♭ major

..

FE (→EE1EE2) lacks ​​​​​​​ raising a1 to a1. The patent mistake was corrected in GE and EE3.

category imprint: Interpretations within context; Differences between sources

issues: EE revisions , Errors in FE , GE revisions , Omission of current key accidentals , Errors repeated in EE

b. 274

composition: Op. 16, Rondo in E♭ major

..

In FE (→EE1), there is no  raising a2 to a2. The error, obvious in this context, may have occurred already in [A]. The necessary accidental was added in GE and EE2 (→EE3). Similarly in bar 290.

category imprint: Interpretations within context; Differences between sources

issues: Errors in FE , GE revisions , Omission of current key accidentals , Errors repeated in EE

b. 289-290

composition: Op. 16, Rondo in E♭ major

..

In FE (→EE), in bar 290 (which opens a new great stave) the slur begins from the 1st note, even though the slur that started on the last note of the previous bar should be continued. The inaccuracy was corrected only in GE.

category imprint: Graphic ambiguousness; Differences between sources

issues: Inaccuracies in FE , GE revisions , Uncertain slur continuation , Errors repeated in EE

b. 305

composition: Op. 16, Rondo in E♭ major

..

FE (→EE1) has a c​​​​​​​in the chord at the end of the bar. It must be a mistake (false relation with the preceding note in the R.H., c2). The erroneous ​​​​​​​ was removed in GE and EE2 (→EE3).  

category imprint: Differences between sources

issues: EE revisions , Errors in FE , GE revisions , Errors repeated in EE

b. 326

composition: Op. 16, Rondo in E♭ major

..

In FE (→EE), there are no naturals raising the A1-A octave to A1-A in the L.H. and the 3rd a​​​​​​​ semiquaver to a in the R.H. The mistake, patent in this context (cf. analogous bar 328), was corrected in GE and EE2 (→EE3).

category imprint: Interpretations within context; Differences between sources

issues: EE revisions , Errors in FE , GE revisions , Omission of current key accidentals , Last key signature sign , Errors repeated in EE